EPA Methods Update Rule 22: Key Changes and the Role of a Water LIMS

How a Water LIMS Helps Labs Meet MUR 22 Requirements and Prep for the Future
+

Water testing laboratories play a critical role in environmental protection by generating analytical data that supports regulatory compliance, pollution control, and public health decisions under the Clean Water Act (CWA). These labs routinely analyze wastewater effluents, industrial discharges, and other matrices to ensure adherence to National Pollutant Discharge Elimination System (NPDES) permits and other CWA programs. Accuracy, consistency, and up-to-date methodologies are not just best practices—they are legal requirements.

The Environmental Protection Agency (EPA) periodically issues Methods Update Rules (MURs) to reflect technological advances, refine quality assurance/quality control (QA/QC) procedures, and expand approved testing options. The latest development is Methods Update Rule 22 (MUR 22), signed as a proposed rule on December 6, 2024, and published in the Federal Register on January 21, 2025 (90 FR 6967). Public comments were initially due by February 20, 2025. However, the EPA reopened and extended the comment period on February 21, 2025, with a revised deadline of March 24, 2025. A final rule had been anticipated in 2026, though the timeline remains uncertain. Once finalized, MUR 22 will amend and update the tables of approved methods within 40 CFR Part 136 and directly affect how water testing labs perform compliance monitoring.

This blog explains MUR 22 in clear terms: what it proposes, which labs must prepare, key changes, compliance requirements, common challenges, best practices, and how a modern water Laboratory Information Management System (LIMS) can streamline adoption. Labs that act now will transition smoothly and maintain data integrity for regulatory reporting.

What is EPA’s Methods Update Rule 22?

EPA’s MURs keep the list of approved analytical methods in 40 CFR Part 136. These methods are the only ones permitted for CWA compliance monitoring unless an alternative is explicitly approved. MURs incorporate new technologies, improve data quality, and give labs and permittees more flexible, accurate options.

MUR 22 proposes several targeted updates:

  • Promulgation of three new EPA-developed methods.
  • Codification of methods from Voluntary Consensus Standard Bodies (VCSBs).
  • Withdrawal of outdated Aroclor-based PCB methods.
  • Simplification of sampling requirements for two volatile organic compounds (VOCs).
  • Minor technical corrections to existing tables.

Key additions include advanced tools for emerging contaminants such as per- and polyfluoroalkyl substances (PFAS) and more precise polychlorinated biphenyl (PCB) analysis. These changes address evolving environmental priorities while maintaining rigorous QA/QC standards. The rule focuses on effluent analysis under the CWA and does not directly alter Safe Drinking Water Act (SDWA) methods in 40 CFR Part 141, though many labs perform both wastewater and drinking water testing.

Key Objectives of MUR 22

MUR 22 is designed to improve both the quality of analytical data and the efficiency of laboratory operations.

Modernizing Analytical Methods:

Many older EPA methods were developed decades ago and may not reflect current instrumentation or laboratory capabilities. MUR 22 updates these methods to align with modern analytical techniques such as advanced chromatography and spectrometry.

Increasing Flexibility:

The EPA continues to move toward a performance-based measurement system (PBMS). This approach allows laboratories to make certain modifications to methods as long as performance criteria are met.

This flexibility enables laboratories to:

  • Optimize workflows
  • Use newer instrumentation
  • Improve turnaround times

Improving Data Quality

By refining method validation requirements and updating procedures, MUR 22 helps ensure that reported data is:

  • Accurate
  • Reproducible
  • Defensible during audits and inspections

Which Laboratories Must Comply With MUR 22?

Any laboratory generating data for CWA programs must use approved Part 136 methods. This includes:

  • Municipal wastewater treatment plant labs performing NPDES compliance monitoring.
  • Industrial discharge testing facilities (e.g., manufacturing, power plants, refineries).
  • Commercial environmental testing labs contracted for permit-required analyses.
  • Pretreatment program labs supporting publicly owned treatment works (POTWs).
  • State and tribal labs involved in CWA enforcement or monitoring.

Drinking water labs regulated under the SDWA are not directly covered, but many full-service water testing facilities handle both matrices. When these labs report CWA-related results (e.g., for industrial clients or integrated water utilities), MUR 22 will apply to the wastewater portion. Labs accredited to ISO/IEC 17025, NELAC/TNI, or state programs must also update their scope of accreditation once the rule is final.

Key Changes and Requirements Introduced by MUR 22

Once finalized, MUR 22 will require labs to adopt the following:

  1. New EPA Methods

    • EPA Method 1633A: Measures 40 PFAS compounds in wastewater and seven other matrices.
    • EPA Method 1621: Determines adsorbable organic fluorine (AOF) as a screening tool for total organofluorine.
    • EPA Method 1628: Quantifies all 209 PCB congeners (replacing less specific Aroclor methods).
  2. VCSB Methods Codified
    • ASTM D8421 for the same 40 PFAS compounds.
    • Standard Method 4500-PAA for peracetic acid.
    • Standard Method 4500-H₂O₂ for hydrogen peroxide.
  3. Withdrawals and Simplifications
    • Removal of seven Aroclor PCB parameters (1016, 1221, 1232, 1242, 1248, 1254, 1260) and their associated methods.
    • Simplified sampling and preservation for acrolein and acrylonitrile to align with other volatile organic compound (VOC) methods.
    • Minor corrections to tables for clarity and consistency.

Labs must follow the exact procedures, holding times, preservation requirements, and QA/QC protocols in the approved methods. Data generated with withdrawn methods will no longer be acceptable for NPDES reporting after the effective date (typically 60–90 days after final publication).

What Water Testing Laboratories Must Do

MUR 22 is not just a regulatory update—it requires action from laboratories to ensure compliance.

Review Approved Methods

Laboratories should:

  • Compare their current methods with updated EPA-approved methods
  • Identify any changes introduced in MUR 22
  • Determine whether method updates are required

Failing to use approved methods can lead to non-compliance during audits or inspections.

Validate Method Changes

If a laboratory adopts new methods or modifies existing ones, it must:

  • Perform method validation
  • Document performance characteristics
  • Demonstrate equivalency or compliance with EPA criteria

Validation ensures that analytical results remain accurate and defensible.

Update Standard Operating Procedures (SOPs)

All changes resulting from MUR 22 must be reflected in laboratory documentation, including:

  • SOPs
  • Work instructions
  • Quality manuals

Outdated documentation is a common compliance gap.

Train Laboratory Personnel

Laboratory staff must be trained on:

  • New or updated methods
  • Changes in procedures
  • Updated quality control requirements

Training ensures consistency and reduces the risk of errors.

Maintain Proper Documentation

Regulatory compliance depends heavily on documentation. Laboratories must maintain:

  • Method validation records
  • Calibration data
  • Quality control results
  • Audit trails
  • Chain of Custody

This documentation is essential during inspections and audits.

Compliance Risks and Challenges

Implementing MUR 22 can present several challenges for water testing laboratories.

1. Keeping Up with Regulatory Changes

Frequent updates to EPA methods can make it difficult for laboratories to stay current. Missing an update can result in non-compliance.

2. Managing Method Transitions

Switching to new or updated methods may require:

  • New instrumentation
  • Staff retraining
  • Workflow adjustments

These transitions can temporarily impact productivity.

3. Ensuring Data Consistency

When methods change, laboratories must ensure that historical data remains comparable to new results. This may require additional validation and documentation.

4. Managing Documentation

Regulatory compliance requires extensive documentation, which can be difficult to manage manually.

How a Water LIMS Supports Compliance with MUR 22

While compliance ultimately depends on policies and analyst expertise, a modern water LIMS dramatically simplifies adoption of new regulatory methods like those in MUR 22 and enforces workflow rules to be followed.

How a Water LIMS Supports Compliance with MUR 22
  • A water LIMS designed for wastewater and drinking water testing labs provides centralized data management that eliminates silos and supports full EPA, ISO/IEC 17025, NELAC, and GLP compliance. 
  • Instrument integration allows seamless import of raw data from LC/MS/MS, ICP-MS, GC, and other platforms used for PFAS, AOF, and PCB congeners—eliminating manual transcription errors that could invalidate results under strict Part 136 QA/QC rules.
  • Automated QA/QC features calculate control limits, generate trend charts based on mean and standard deviation, and flag out-of-specification results before release. This is especially valuable for new PFAS methods that demand rigorous matrix spike, duplicate, and blank checks. 
  • Sample tracking with electronic chain-of-custody (CoC) and GPS-stamped field data ensures traceability from collection through analysis—critical for NPDES audits.
  • Role-based access controls and complete read-only audit trails document every data change, user action, and approval step, providing the transparency regulators expect. 
  • Custom reporting templates automatically populate Certificates of Analysis (COAs) with EPA-required formats, including images, charts, and calculated results, for direct eDMR submission to federal and state agencies.
  • Calibration and maintenance scheduling with automated alerts keeps instruments compliant with method-specific requirements. 
  • Document management stores validated SOPs records, while staff competency tracking ensures only qualified analysts perform MUR 22 methods.

Together, these capabilities turn the complexity of MUR 22—new analytes, revised tables, and heightened QA/QC—into streamlined, auditable processes that protect data integrity and support regulatory reporting.

How Often Should Laboratories Review EPA Method Updates?

Laboratories should review EPA method updates at least annually and whenever new rules like MUR 22 are released. However, best practice is to monitor updates continuously to ensure timely compliance.

Conclusion

Water testing laboratories sit at the intersection of environmental science, regulatory enforcement, and public protection. MUR 22 represents EPA’s ongoing commitment to modern, accurate analytical tools—particularly for challenging contaminants like PFAS and PCBs. By understanding the proposed changes, preparing method validations, and leveraging technology such as a purpose-built water LIMS, labs can adopt the updates efficiently while continuing to deliver reliable data for NPDES compliance and environmental stewardship.

Strong preparation, staff training, robust quality systems, and digital tools form the foundation of successful compliance. Labs that embrace MUR 22 proactively will not only meet regulatory expectations but also strengthen their reputation for scientific excellence and data reliability with clients, regulators, and communities.